Model 050SA is our most quiet high pressure misting pump featuring:
Three self-priming pistons
0.18 Gallons Per Minute (GPM) capacity
Integrated water supply sensor and automatic pressure regulation
Anti-drip HP solenoid valve
12V 150W brushless DC servo motor with motor overheat protection
Outdoor rated 12VDC power supply
Its ceramic-coated stainless steel pistons and aircraft anodized aluminum body makes it the most long-lasting misting machine on the market with minimal maintenance requirements. Automatic pressure regulation allow it to operate with just 1 or 2 nozzles connected. Perfect for smaller spaces and for adding misting to a fan. Comes with wireless remote.
Specifications
Power: 120VAC 60Hz 150W
Maximum flow: 0.18GPM
Minimum flow: 0.05GPM
Pressure: 580, 800, and 1000PSI user selectable
Operating temperature: 40°F to 130°F
Storage temperature: 34°F to 130°F
Noise: 48dB
3/4 inch garden hose connection
Max / Min nozzles at full pressure
orifice size diameter
min nozzles
max nozzles
0.1mm
2
23
0.15mm
1
14
0.2mm
1
8
0.3mm
NA
NA
Installation requirements
Misting pump must be installed at or above grade level, and away from direct sunlight and rain exposure. It must not be submerged in water for any period of time.
Water inlet can be fed with water from the city water line (requires 3/4 garden hose male connection) or gravity fed with water from a bucket. Potable water only. Included polyether tubing should be used to connect pump to the faucet directly as garden hoses often react with chlorine in water and cause chlorine smell in misted air. Integrated water switch will shut off pump when there is no water present.
Power: Outdoor rated 120V NEMA 5-15R GFCI power outlet is required.
Pump oil must be added before powering ON for the first time.
Maintenance
Requires simple oil change every 1000 hours, or once a year.
May require water, o-ring, and oil seal change after 1000-2000hrs (2000hrs translates to 7 years of moderate use or 3 years of very heavy use)
Filter change (if optional 0.5 micron filter is used) based on filter specifications. Filter cleaning if standard (included) filter is used is recommended at least once a season.
In The Box
Model 050SA pump with basic accessories:
Pump oil
Syringe for dispensing oil
15ft high pressure plastic tube (black color) for connecting pump outlet to the misting line
Standard stainless steel mesh filter with polyether tubing and quick connect adapter for direct connection to pump inlet
Quick connect to 1/4 inch slip lock adapter for connecting pump outlet to high pressure line