Search our shop

050SA Plastic Tubing Misting Kit

Size Guide
aerMist Sizing Chart
high-pressure-misting-system-sizing-chart
aerMist Sizing Chart
high-pressure-misting-system-sizing-chart

Select Nozzle Number | Misting Length
Select Nozzle Size
Select Nozzle Type

Cool your smaller spaces quietly.

  • Ideal for smaller spaces, up to 400 sqft.

    Our 050SA plastic tubing high pressure misting kit comes with model 050SA high pressure misting pump and all of the tubing, nozzles, fittings, and accessories you will need to install selected misting line length in "I" shape and cool outdoor patio with evaporative cooling. Please check "In The Box" section to verify you have the necessary fittings for your installation. Model 050SA pump is our most quiet high pressure misting pump featuring:
    • 3 year pump warranty
    • Three self-priming pistons
    • Interval mode misting with 4 settings: non-stop, mist 3sec - pause 10sec, mist 10sec - pause 10sec, mist 20sec - pause 10sec
    • User selectable pressure output: 580PSI, 800PSI, & 1000PSI
    • 0.18 Gallons Per Minute (GPM) capacity
    • Integrated water supply sensor and automatic pressure regulation
    • Anti-drip HP solenoid valve
    • 12V 150W brushless DC servo motor with motor overheat protection
    • Outdoor rated 12VDC power supply
    Its ceramic-coated stainless steel pistons and aircraft anodized aluminum body makes it the most long-lasting misting machine on the market with minimal maintenance requirements. Automatic pressure regulation allow it to operate with just 1 or 2 nozzles connected. Perfect for smaller spaces and for adding misting to a fan.
    Comes with wireless remote.
    Available with both ceramic and stainless steel nozzle orifice type. Stainless steel orifice is more resistant to mild freezing temperatures but has somewhat shorter life. Ceramic orifice has longer life but will crack when exposed to temperatures below freezing point if there is any water left in it. Draining water from misting lines will not remove water from the nozzle, so if you live in areas where temperatures drop below freezing even for short periods, use stainless steel orifice nozzles. If your water has scale causing minerals such as calcium, magnesium, and iron (defined as "hard water"), or fine sediment, consider upgrading to water filter + scale inhibitor to prevent premature pump failure, and clogged and dripping nozzles caused by scale buildup. Damage from scale and fine sediment is not covered under the warranty.
  • Specifications
    • Power: 120VAC 60Hz 150W
    • Maximum Flow: 0.18GPM
    • Minimum Flow: 0.05GPM
    • Pressure: 580, 800, and 1000PSI user selectable
    • Interval mode misting with 4 settings: non-stop, mist 3sec - pause 10sec, mist 10sec - pause 10sec, mist 20sec - pause 10sec
    • Dimensions: 15in (L) x 8in (W) x 8in (H)
    • Pump operating temperature: 40°F to 130°F
    • Pump storage temperature: 34°F to 130°F
    • Noise: 48dB
    • Water connection: 3/4 inch garden hose thread
    • Wireless range: up to 100ft in open space
    • Remote battery: 2 x CR2016
    • Misting nozzle wet storage temperature
      • Ceramic orifice: 33°F to 140°F
      • Stainless steel orifice: 22°F to 140°F

    Max / Min nozzles at full pressure

     orifice size diameter  min nozzles  max nozzles
    0.1mm   (0.004 inch) 7 23
    0.15mm (0.006 inch) 5 15
    0.2mm   (0.008 inch) 4 10
    0.3mm   (0.012 inch) NA
    NA
  • Installation requirements

    • Misting pump must be installed at or above grade level, and away from direct sunlight and rain exposure. It must not be submerged in water for any period of time.
    • Water inlet can be fed with water from the city water line (requires 3/4 garden hose male connection) or gravity fed with water from a bucket. Potable water only. Included polyether tubing should be used to connect pump to the faucet directly as garden hoses often react with chlorine in water and cause chlorine smell in misted air. Integrated water switch will shut off pump when there is no water present.
    • Power: Outdoor rated 120V NEMA 5-15R GFCI power outlet is required.
    • Pump oil must be added before powering ON for the first time.
  • Maintenance

    • Requires simple oil change every 1000 hours, or once a year.
    • Requires winterization for areas where temperatures drop below freezing. Water must be drained from all tubing and filters, pump and ceramic nozzles removed and stored at above freezing temperatures.
    • May require water, o-ring, and oil seal change after 1000-2000hrs (2000hrs translates to 7 years of moderate use or 3 years of very heavy use)
    • Filter change (if optional 0.5 micron filter is used) based on filter specifications. Filter cleaning if standard (included) filter is used is recommended at least once a season.
  • In The Box

    • Model 050SA pump with basic accessories:
      • Pump oil 
      • Syringe for dispensing oil
      • Standard stainless steel mesh filter with polyether tubing and quick connect adapter for direct connection to pump inlet
      • Quick connect to 1/4 inch slip lock adapter for connecting pump outlet to high pressure line
      • Plastic tubing cutters
      • Wireless (key fob) remote
    • High pressure misting nozzles (size, number, and orifice material according to selection)
    • High pressure plastic tubing (black color) spool, misting line length + 15ft
    • Rubberized pipe hangers (number of nozzles selected x 2 + 5pcs)
    • Straight slip lock fitting with nozzle port (same number as the number of nozzles selected)
    • L type (corner) slip lock fitting QTY 1
    • End slip lock fitting with nozzle port QTY 1
    • Plastic tubing sharpener tool QTY 1